Flanged Magnetically Coupled Stirred Reactor

HJCHEM benchtop high pressure lab reactors, also referred to as laboratory autoclave reactors, are configurable systems designed for laboratory synthesis, catalysis, hydrogenation, materials research and other reactions requiring controlled pressure, temperature and agitation.

Standard vessel volumes range from 10 mL to 1 L, with multiple options for materials, stirring methods, vessel closures, heating and cooling configurations.

Each reactor is configured according to the actual process conditions. Pressure rating, operating temperature, SS316L, Hastelloy C276, titanium or Zirconium 702 wetted parts, magnetic or magnetically coupled mechanical stirring, flanged or one-touch quick-opening closures, and Siemens PLC control can be selected according to the application.

  • 10 mL–1 L Standard Volumes
  • 10 / 20 / 35 MPa & Custom Pressure
  • 300 / 400 / 500°C & Custom Temperature
  • Siemens PLC Touchscreen Control & data records and export

Technical Specifications

ItemStandard / Available Configuration
Volume10 / 25 / 50 / 100 / 250 / 500 / 1000 mL
Wetted MaterialSS316L / Hastelloy C276 / Titanium Grade 2 (TA2) / Zirconium 702 (UNS R60702) / other compatible alloys
Pressure10 / 20 / 35 MPa; custom pressure ratings available
Heating & CoolingElectric Heating: 300 / 400 / 500°C; optional internal cooling coil.
Jacketed Option: External heating & cooling circulator, including sub-zero operation.
Electric Heating Control ModesReactor Temperature Control · Ramp Rate Control · Programmed Temperature Control · Furnace Temperature Control
StirringMagnetic stir bar / Magnetically coupled mechanical agitator (≥50 mL)
ClosureFlanged / One-touch quick-opening
Control SystemSiemens PLC + touchscreen
Touchscreen FunctionsReactor temperature, stirring speed and furnace temperature display & adjustment; real-time pressure display
Data & SafetyTemperature/pressure data recording and export; adjustable temperature/pressure alarm limits
Standard FittingsGas inlet with dip tube · Vent valve · Thermocouple · Pressure sensor · Pressure gauge · Rupture disc
Optional FunctionsCooling coil · Online sampling · Condenser · Charging funnel · Isobaric liquid feeding · High-pressure metering pump · Gas mass flow meter

Notes:
Pressure, temperature, material and closure options depend on vessel size and process conditions. Final dimensions, port arrangements and configurations will be confirmed in the approved technical drawing.

Configurable for Different Laboratory Reactions

magnetic-vs-mechanical-stirring-under

HJCHEM benchtop high pressure lab reactors are designed as configurable laboratory autoclave reactor systems rather than fixed-specification units. The final configuration is selected according to vessel volume, reaction pressure, operating temperature, reaction media, agitation requirements and preferred operating method.

A high pressure autoclave reactor can be configured with a magnetic stir bar or magnetically coupled mechanical agitator, flanged or one-touch quick-opening closure, electric heating or jacketed temperature control, and optional cooling, feeding, sampling and gas-control functions.

For small-volume laboratory work, a compact lab autoclave reactor can be configured from 10 mL to 1 L with different pressure ratings, wetted materials and control options. Where stronger mixing is required, a stirred autoclave reactor with magnetically coupled mechanical agitation can be selected for viscous liquids, slurries, suspended solids or stronger gas-liquid mixing.

For larger capacities or different laboratory layouts, comparing benchtop and floor-standing pressure reactors can help determine the most suitable reactor configuration.

Quick-opening or flanged closures are selected according to vessel size, design pressure and the required operating convenience. Pressure, temperature and material specifications are confirmed according to the complete reactor design and actual process conditions.

Why Choose HJCHEM Benchtop High Pressure Reactors?

benchtop-reactor-cross-section

Application-Based Configuration

Each high pressure reactor is configured according to the actual process rather than supplied as one fixed model. Vessel volume, pressure and temperature, material, stirring method, closure structure and auxiliary functions can be selected according to the reaction requirements.

Multiple Material Options

Standard and optional wetted materials include SS316L, Hastelloy C276, Titanium Grade 2 and Zirconium 702, with other compatible materials available for specific chemical environments.

Siemens PLC Control

The laboratory autoclave reactor can be equipped with Siemens PLC and touchscreen control for real-time temperature and pressure monitoring, data recording, historical data export, adjustable alarm limits and process status display.

Flexible Stirring & Closure Options

Magnetic stir-bar agitation and magnetically coupled mechanical stirring are available. Flanged and one-touch quick-opening structures can be selected according to the required design pressure and operating convenience.

Expandable Process Functions

Optional functions include internal cooling coils, online sampling, condensers, charging funnels, isobaric liquid feeding, high-pressure metering pumps and gas mass flow control.

HJCHEM benchtop-high-pressure-reactor

Request a Custom Configuration

Looking for a benchtop high pressure reactor for your laboratory?

HJCHEM can help configure the reactor based on your process requirements, including vessel volume, operating pressure and temperature, wetted materials, stirring method, closure type and auxiliary functions.

Please share your requirements:

  • Vessel volume

  • Operating pressure and temperature

  • Reaction media and gases

  • Preferred stirring and closure options

  • Additional feeding, cooling or sampling requirements

Contact HJCHEM for a customized configuration and quotation.

CONTACT US